Device description

5.6 LED display

5.6
LED display
The following figure shows the arrangement of the LEDs on the SCALANCE XCM-100.
LED "A" (red alarm LED)
The "A" LED indicates an alarm status of the device.
LED color
LED status
Red
Lit
-
Off
LEDs "P" (green/yellow port LEDs)
The port LEDs indicate the status of the ports or the fault mask.
Port LED
LED color
P1
Green
P1
Yellow
P2
Green
P2
Yellow
P1 + P2
Green
20
SIEMENS
SIEM
A
P1
P2
A
L1
L2
P1
P2
P1
P2
L1
SELECT/
L2
SET
A1
A2
L1
M1
Meaning
SCALANCE XCM-100 detects and error. At the same time, the signaling contact opens.
The following faults/errors are detected:
1. Link down event on a monitored port.
2. Loss or shortfall of the power supply below 14 V on one of the two power supplies.
No error detected by the SCALANCE XCM-100.
LED status
Lit
Flash
Lit
Flash
Flash
SCALANCE
XCM102
L2
M2
Meaning
Link exists, no data reception at port
Link exists, data reception at port
Link exists, no data reception at port
Link exists, data reception at port
Setting or display of the fault mask
Operating Instructions, 07/2022, C79000-G8976-C659-01
SCALANCE XCM-100 Media Converter