• Create the ladder program to control the TRIG and IN5 input signals so that they do not turn ON while the BUSY
signal is ON. If not, a TRIG input error will occur and the ERROR signal will turn ON.
• Operation When the Sensor Power Supply Is Turned ON
The BUSY signal will operate as shown below when the Sensor's power supply is turned ON.
Create the ladder program in the PLC or other external device so that the BUSY signal is ignored while it turns OFF,
ON, and OFF again for up to 5 s after the power supply is turned ON.
Power supply
BUSY
* Depends on the scene data.
Note
You can mount a Parallel Interface Sensor Data Unit to enable using other signals and increase the number of sig-
nals that you can use with parallel communications.
And in addition to outputting OR judgement results, you can also use a Parallel Interface Sensor Data Unit to output
the judgement results of judgement conditions that you set for parallel output (called parallel judgement output) and
the results of measurement values and expressions for inspection items (called parallel data output).
8-2 Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit: p. 302
Configuring the Operation
The following settings can be selected depending on the system configuration and application.
Type of change
Changing the type of measurement trigger
Changing the output method of the judgement results
Changing the polarity of the BUSY output
Changing the BUSY output condition
Changing the polarity of the output signals (OUT1 to
OUT3)

Setting the Measurement Trigger

The measurement trigger can be chosen from the following two types:
• One-shot measurement: One measurement is performed for each external trigger.
• Continuous measurement: Measurements are performed continuously.
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
24 V
0 V
1.5 s
ON
OFF
Sensor system is initializing
Change
Performing continuous measurements
Obtaining individual judgement results
Adjust the judgement output timing
Changing the judgement output ON conditions
Reversing the polarity of the BUSY signal
Adjusting the end timing of the BUSY signal
Reversing the output polarity of OUT1 to OUT3
Turns OFF when the
3.5 s*
Sensor is ready for
operation.
Reference
p. 283
p. 287
p. 288
p. 290
p. 290
p. 290