Command List

The following table lists the no-protocol commands.
Commands that can be used in no-protocol Ethernet communications are listed below.
Type of command
Command
Measurement control
MEASURE
and measurement acqui-
MEASURE /C
sition commands
MEASURE /E
Utility commands
CLRMEAS
CLRERR
DATASAVE
MODEL
RESET
TEACH
Scene control com-
SCENE
mands
SCENE Scene_number
Data acquisition/setting
POSITIONDATA
commands
Item_number
External_reference_data_nu
mber
POSITIONDATA
Item_number
External_reference_data_nu
mber Setting
ITEMDATA
Inspection_item_number
External_reference_data_nu
mber
ITEMDATA
Inspection_item_number
External_reference_data_nu
mber Set_value
ITEMDATA2
Inspection_item_number
External_reference_data_nu
mber
ITEMDATA2
Inspection_item_number
External_reference_data_nu
mber
Text_strings
VERGET/S
VERGET/H
ERRGET
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with TCP No-protocol Communications
Abbreviation
Function
M
Executes one measurement. p. 412
M /C
Starts continuous measure-
ments.
M /E
Ends continuous measure-
ments.
None
Clears the measurement val-
ues.
None
Clears the error output status
(error signal and error indica-
tor).
None
Saves the settings data to the
Sensor.
None
Re-registers the models for
registered Search inspection
items.
None
Restarts the Sensor.
None
Executes teaching for all
applicable inspection items.
S
Acquires the current scene
number.
S Scene_number
Changes the scene number
being used.
PD
Acquires data from a position
Item_number
compensation item or filter
External_reference_data_nu
item.
mber
PD
Sets data for a position com-
Item_number
pensation item or filter item.
External_reference_data_nu
mber Setting
ID Inspection_item_number
Acquires the inspection item
External_reference_data_nu
data.
mber
ID Inspection_item_number
Sets the inspection item data. p. 423
External_reference_data_nu
mber Set_value
ID2 Inspection_item_number
Acquires the text string data
External_reference_data_nu
of the specified inspection
mber
item.
ID2 Inspection_item_number
Sets the text string data of the
External_reference_data_nu
specified inspection item.
mber
Text_strings
None
Acquires the version informa-
tion of the Sensor software.
None
Acquires the Sensor model
information.
None
Acquires the latest error code
of the Sensor.
Reference
p. 413
p. 414
p. 415
p. 416
p. 416
p. 417
p. 417
p. 418
p. 418
p. 419
p. 420
p. 420
p. 422
p. 424
p. 425
p. 426
p. 427
p. 428
411