Clearing Measurement Values: 280F 00102010
This command clears the measurement values.
● Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● End Codes
End code (hex)
0000
FFFF
Clearing Errors: 280F 00102040
This command clears the error output status (error output and error indicator).
● Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● End Codes
End code (hex)
0000
FFFF
434
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Vision Sensor command code
(4 bytes)
00102010
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
Vision Sensor command code
(4 bytes)
00102040
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
Vision Sensor command code
(4 bytes)
00102010
Vision Sensor command code
(4 bytes)
00102040