Registering the Measurement Reference Again
The model and reference color can be re-registered with commands from an external device, such as a PLC,
based on the image that was just input when the line process was changed.
Inspection item
Search, Shape Search II
Color Data
Edge Position, Edge Width, Area
Note
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be re-registered for all inspection items.
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Input] − [Input mode]
Press [Expand mode].
Wiring
Color
Signal
State
Gray
IN0
OFF
Green
IN1
OFF
Red
IN2
OFF
White
IN3
ON
Purple
IN4
OFF
Yellow
IN5
ON
Orange OUT1 (BUSY)
--
Timing Chart
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Re-registered data
Model data
Reference color (hue, saturation, and brightness)
None
Description
Command parameter for registering the model
again
Command input for registering the model again
Processing in progress (default)
Allow 5 ms min. and then turn
ON IN5.
ON for 1 ms min.
Start re-registering
End re-registering
The signals shown at the left are
used.
Refer to the following information for
signal wiring.
2-4 Wiring: p. 42
1 Turn OFF IN 0 to IN4 and turn ON
IN3.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to register the
model data and reference color again
from the image that was just input.
3 The BUSY signal turns ON while the
parameters are being re-registered.