● Connection Settings
Parameter
Originator device (PLC)
Target device (Vision Sen-
sor)
Packet interval (RPI)
*1
If multi-cast connections are used, however, use an Ethernet switch that has multi-cast filtering, unless the tag set is received by all nodes
in the network.
*2
Set the same value as you set for the refreshing task period in the EtherNet/IP communications settings.
Important
• If I/O memory addresses are specified for the communications areas, the information in the communications areas
will be cleared when the operating mode of the PLC changes unless addresses in the CIO Area, which are main-
tained, are specified.
• The following assembly object is required to specify instances when the EDS file is not used.
Assembly Object Settings
Parameter name
Instance ID
340
Outputting Data and Controlling Operation through EtherNet/IP
Input tag set
Connection type
Output tag set
Output tag set
Input tag set
Setting
100
101
Setting
PLC_tag_set_name-[**Byte]
**: This is the total size of the response area and
output area that you set.
Any (default: multi-cast connection)
PLC_tag_set_name-[20Byte]
Input_101-[**Byte]
**: This is the total size of the response area and
output area that you set.
Output_100-[20Byte]
*2
Any (default: 20.0)
Remarks
Output connection
Input connection
*1
FQ2-S4 User's Manual