Measurement Data That Can Be Logged for OCR

Parameter
Judgement
Similarity
Stability
Number of read characters on
line 1
Number of read characters on
line 2
Number of read characters on
line 3
Number of read characters on
line 4
Individual similarity
Individual stability

Failure to Read Characters

• Failure to Read Characters during Teaching
• The read results may be unstable if the contrast is low. Adjust the brightness to improve the contrast.
• The characters may not be in the measurement region. Check to see if the measurement region is set cor-
rectly.
• The specified character format may not agree with the format of the read characters. Check the character
format.
FQ2-S4 User's Manual
Setting
−2: Not measured,
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
−16: Measurement timeout error,
−17: Format not entered error
0 to 100
0 to 100
0 to 32
0 to 32
0 to 32
0 to 32
0 to 100
0 to 100
Description
This is the judgement result.
This is the lowest similarity of the read characters.
This is the lowest stability of the read characters.
This is the number of characters that were read on line 1.
This is the number of characters that were read on line 2.
This is the number of characters that were read on line 3.
This is the number of characters that were read on line 4.
This is the similarity of read character N (N = 0 to 127).
This is the stability of read character N (N = 0 to 127).