11.2

Pulse width trigger mode

The camera exposure starts by trigger signal.
In this trigger mode with positive trigger polarity, camera exposure starts at rising edge of trigger signal and stops
at falling edge of trigger signal.
Therefore, In case of exposure positive polarity is selected, the exposure periods (exposure time) are high states
of trigger signal.
Overlap mode
Input Trigger Signal
(Positive)
Exposure Time
Image Out
FVAL
Fast trigger mode
Input Trigger Signal
(Positive)
Exposure Time
Image Out
FVAL
Note.1: The exposure time sets by active pulse width of trigger signal.
No FVAL output without any trigger signal.