Omron FQ2-S4 User Manual page 438

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Resetting the Sensor: 280F 0010F010
This command resets the Sensor.
● Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● Response Format
If process is completed normally, the Sensor is reset. There is therefore no response.
External Teaching: 280F 00104020
This command performs teaching for all applicable inspection items.
● Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
● End Codes
End code (hex)
0000
FFFF
436
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Vision Sensor command code
(4 bytes)
0010F010
Vision Sensor command code
(4 bytes)
00104020
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
Vision Sensor command code
(4 bytes)
00104020
FQ2-S4 User's Manual

Advertisement