Menu command
Communication
type
When the com-
munications type
is TCP no-proto-
col or FINS/TCP
no-protocol
Connec-
tion mode
IP address Sets the IP address to which to output
Port No.
When the com-
munications type
is RS-232C no-
protocol
Baud rate Set the baud rate to use for RS-232C
Data
length
Parity
Stop bit
Flow con-
trol
Delimiter
Interval
timeout
(text)
Interval
time-
out(after
Xoff
reception)
Communication
type
Area set-
tings(Only when
communications
type is PLC Link)
484
Menu Tables
Description
Sets the communications type to use to
output no-protocol data.
Sets whether to communicate with the
communications devices as a server
device or a client device.
no-protocol data.
* Setting is not possible if the connection
mode is set to a TCP server.
Sets the output port number.
* Setting is not possible if the connection
mode is set to a TCP server.
communications.
Sets the data length.
Sets the parity.
Sets the number of stop bits.
Sets the controls for the flow of commu-
nications with the software.
Set the delimiter to add to the end of
commands and responses.
Timeout [s] Set the time in seconds to
generate a timeout error.
Timeout [s] Set the time in seconds to
generate a timeout error.
Sets the communications type to use for
EtherNet/IP or PLC Link outputs.
Sets the area to write command data to
the Sensor.
Control inputs, command codes, and
command parameters are written to this
area.
Set the first address of the command
area.
Setting range
Invalid (default), No protocol (TCP), No
protocol (FINS), No protocol (RS-232C)
TCP server (default), TCP client
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
(Default:10.5.5.111)
0 to 65535 (Default: 9600)
2400, 4800, 9600, 19200, 38400, 57600,
or 115200 (default: 38400)
7bit or 8bit (default: 8bit)
None, Odd, Even (default: None)
1bit, 2bit (default: 1bit)
None, Xon/Xoff (default: None)
CR, LF, or CR+LF (default:CR)
1 to 120 s, 0: Not monitored.
(default: 0 s)
1 to 120 s, 0: Not monitored.
(default: 0 s)
Invalid (default), PLC link (SYSMAC)
PLC link (MELSEC), EtherNet/IP
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
0 to 99,999 (default: 0)
Data
Refer-
ence
System
p. 402,
p. 448
System
p. 402
System
p. 402
System
p. 402
System
p. 448
System
p. 448
System
p. 448
System
p. 448
System
p. 448
System
p. 448
System
p. 448
System
p. 448
System
p. 375
p. 376
System
System
FQ2-S4 User's Manual