When operating in this mode, exposure synchronizes trigger signal.
The exposure time can be controlled by pulse width of Frame Start trigger.
When the polarity on LineInverter is positive (false), exposure can be controlled at a period of High level of input
trigger signal.
When the polarity on LineInverter is negative (true), exposure can be controlled at a period of Low level of input
trigger signal.
To operate the camera in this mode, following settings have to be set.
・ExposureMode: TriggerWidth
・TriggerSelector: FrameStart
・TriggerMode: On
(*) On TriggerMode except FrameStart should be set Off.
Timing
トリガー入力(正極性)
トリガー入力(負極性)
露光
Image Out
映像出力
Delay time on exposure start timing in sensor Jitter (unit:
STC-LBS34U3V-SWIR
Product Specifications and User's Guide
Trigger Input
(Positive)
I/O Delay (tIPDLH)
I/O遅延(tIPDLH)
Trigger Input
(Negative)
I/O遅延(tIPDHL)
I/O Delay (tIPDHL)
センサー内部の露光開始遅延
Exposure Start Duration
inside of sensor
Exposure
Image Output Format
8bits
10bits / 10bits Packed
12bits / 12bits Packed
tPW
I/O遅延(tIPDHL)
I/O Delay (tIPDHL)
tPW
I/O Delay (tIPDLH)
I/O遅延(tIPDLH)