Input Format (IN7 to IN0)
IN7 IN6 IN5 IN4 IN3 IN2 IN1 IN0
Command
Execution
Changing the Scene
This command changes the scene to shift to a different process.
Parameters
Execution
Command
IN7
IN6
1
01
Timing Chart
Run Mode entered.
ON
RUN signal
OFF
IN0 to IN6
signals
ON
IN7 signal
OFF
Allow 5 ms min.
and then turn ON IN7.
ON
ON
BUSY signal
OFF
OFF
ON
ACK signal
OFF
Output Signals
Signal
Function
RUN
This signal is ON while the Sensor is ready to take measurement and it is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal indicates that the Sensor is currently changing the scene.
Do not input the next command while the BUSY signal is ON. The process that is currently being executed and the com-
mand that is input will not be executed correctly.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK output
time.
318
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
IN5
IN4
IN3
Input the scene number as a binary value.
0
10100001 (Changes to scene 1.)
ON for 1 ms min.
Command execution
IN2
IN1
IN0
Setup Mode entered.
ACK output time
Input example
10100001
(Changes to scene 1.)