Omron FQ2-S4 User Manual page 358

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Example: Setting Example for Variables to Access the Command Area
Command Area (PLC Output Tag D0)
I/O memory
address
15
D0
ERCLR
D1
Commands (EtherNet/IP)
This section describes the EtherNet/IP commands.
● Measurement Control Commands
Command code in
command area (hex)
00101020
00101030
● Utility Commands
Command code in
command area (hex)
00102010
00102020
00103010
00104010
00104020
0010F010
00205000
● Scene Control Commands
Command code in
command area (hex)
00201000
00301000
356
Outputting Data and Controlling Operation through EtherNet/IP
1
TRIG
Command name
Start Continuous Measure-
ments
End Continuous Measure-
ments
Command name
Clear Measurement Values
Clear Data Output Buffer
Save Data in Sensor
Re-register Model
Teach
Reset
Get Latest Error Information
Command name
Get Scene Number
Select Scene
Variables Used to Access the Command Area
in the PLC from the User Program
0
Variable name
EXE
DSA
a (Assigned to the EXE signal.)
b (Assigned to the TRIG signal.)
c (Assigned to the ERCLR signal.)
d (Assigned to the DSA signal.)
Function
Executes continuous measurements.
Ends continuous measurements.
Function
Clears all measurement result values.
Clears all data in the data output buffer.
Saves scene data and system data.
Registers the model again for registered
Search Position Compensation, Shape
Search II Position Compensation, Search,
Shape Search II, or Sensitive Search inspec-
tion items.
Executes teaching for all inspection items.
Resets the Vision Sensor.
Acquires the latest error information.
Function
Acquires the current scene number.
Changes to the specified scene number.
Settings
AT
Data type
specification
D0.0
BOOL
D0.1
BOOL
D0.15
BOOL
D1.0
BOOL
Reference
p. 357
p. 358
Reference
p. 358
p. 359
p. 359
p. 360
p. 360
p. 361
p. 361
Reference
p. 362
p. 362
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading

Table of Contents