Fins Command Details - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

FINS Command Details

Executing Measurements: 280F 00101010
This command executes one measurement.
If Ethernet output is not set, only the measurement is performed.
If Ethernet output is set, the measurement is performed and the result is returned as response data.
● Command Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00101010
● Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
● End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
● Parameter Descriptions
Measurement result
• Returns the measurement result as the response when data output is set. The measurement result is
not output when data output is not set.
• Each data item requires 4 bytes.
Up to 1,024 bytes of data can be received.
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00101010
Setting the Data To Output Automatically after Measurements: p. 433
Measurement
result (1,024 bytes)
Measurement
result
433