Omron FQ2-S4 User Manual page 301

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Save Data in Sensor
You can save the current settings (scene data and system data) in the Sensor.
Note
This function can be used in Run Mode only.
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Input] − [Input mode]
Press [Expand mode].
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Orange
OUT1 (BUSY)
Timing Chart
IN0 to IN4
signals
ON
IN5 signal
OFF
ON
BUSY
signal
OFF
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
State
Description
ON
Command parameters for saving data to
the Sensor
OFF
OFF
OFF
OFF
ON
Command input for saving data to the
Sensor
--
Processing in progress (default)
Allow 5 ms min. and then
turn ON IN5.
ON for 1 ms min.
Saving data in
Saving data
Sensor completed.
in Sensor started.
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
2-4 Wiring: p. 42
1 Turn ON IN0 and turn OFF IN1 to IN4.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to save the data
in the Sensor.
299