Adjusting Image Brightness With External Lighting; Adjusting The Brightness - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Adjusting Image Brightness with External Lighting

You can adjust image brightness with external lighting or by setting the Sensor sensitivity.
Using a Strobe Trigger Signal to Control External Lighting
If a Data Unit is connected, you can change the output time of the strobe trigger signal (STGOUT) to adjust the
brightness.
Changing the Output Timing and Output Time of the STGOUT Signal: p. 316

Adjusting the Brightness

You can adjust the shutter speed/gain or the brightness to make images brighter. The setting method depends
on whether HDR Mode is ON or OFF. The setting methods are described below.
HDR Function: p. 65
Important
The exposure time will be longer for higher values of the shutter speed or brightness. This may cause the
image to blur if the object is moving fast. If the Sensor is used on a high-speed line, check that the images are
not blurred under actual operating conditions.
Brightness Correction Mode (FQ2-S4@@@@@/FQ2-S4@@@@@-M)
If the brightness changes inconsistently with each image, turn ON the Brightness Correction Mode.
[Brightness] −
When HDR is ON:
[Gain] −
When HDR is OFF:
When the Brightness Correction Mode is ON, the brightness will be consistent but the timing when images are
taken will be delayed by 25 ms. Make sure that appropriate images of the measured objects are taken when the
Brightness Correction Mode is ON.
Timing Chart When the Brightness Correction Mode Is ON
Taking images begins 25 ms
after the TRIG signal is input.
TRIG signal
ON
(Brightness
OFF
Correction ON)
ON
BUSY signal
OFF
Reference Timing Chart When the Brightness Correction Mode Is OFF: p. 282
Important
If the gain is increased, the brightness will not be stable and measurement values may be inconsistent. We
recommend that you turn ON the Brightness Connection Mode.
FQ2-S4 User's Manual
− [Brightness correction]
− [Brightness correction]
ON for 1 ms min.
ON while the measurement
process is being executed.
Adjusting Image Quality