Executing External Teaching
You can use the image that is currently being input to execute teaching for all of the registered inspection items.
Note
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be external teaching for all inspection items.
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Input] − [Input mode]
Press [Expand mode].
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Orange OUT1 (BUSY)
Timing Chart
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
300
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
State
Description
ON
Command parameter for external teaching
OFF
OFF
ON
OFF
ON
Command input for external teaching
--
Processing in progress (default)
Allow 5 ms min. and then
turn ON IN5.
ON for 1 ms min.
Start external teaching
End external teaching
The signals shown at the left are
used.
Refer to the following information for
signal wiring.
2-4 Wiring: p. 42
1 Turn ON IN0 and IN3 and turn OFF
IN1, IN2, and IN4.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to execute
external teaching.
3 The BUSY signal turns ON while
external teaching is being executed.
FQ2-S4 User's Manual