Changing The Character String That Is Output For Read Errors; Measurement Data That Can Be Used For External Outputs And Calculations 135 Inspection Data That Can Be Logged - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Changing the Character String That Is Output for Read Errors

You can change the character string that is output for read errors.
[Inspect]
[Inspection]
parameter]
[Error string]
Setup Item
Setting Value
Error string
Max. 20 digits (default value:
NG)
Measurement Data That Can Be Used for External Outputs and Calculations
Expression text
Data name
string
JG
Judgment
IN
Index
N
Num. of characters
E
Cell recognition rate
C
Contrast
F
Focus
Inspection Data that Can be Logged
The following values can be logged as inspection data.
Inspection item
−2: No judgement (not measured),
Judgement
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error,
−16: Measurement timeout error
Cell recognition rate
0 to 100
Contrast
0 to 100
Num. of char.
0 to 1024
−2: Verification OFF, or reading error
Index
−1: Verification is NG,
0 to 31: Master data No.
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 252
FQ2-S4 User's Manual
[Add item.]
[2D-code (DPM)]
Description
Sets the text string to be output when a read error occurs.
Description
This is the judgment result.
The verification result (master data No.) is
output.
The number of characters read is output.
Outputs the cell recognition rate.
Outputs the contrast.
Outputs the focus.
Value range
[Details] Tab Page
ASCII code table: p. 116
Data range
−2: No judgment (not measured),
0: Judgment is OK,
−1: Judgment is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error,
−16: Measurement timeout error
−2: Verification OFF,
or reading error
−1: Verification is NG,
0 to 31: Master data No.
0 to 1024
0 to 100
0 to 100
0 to 100
Description
This is the judgement result from the measurements.
Outputs the cell recognition rate.
Outputs the contrast.
Outputs the number of characters that were detected.
Outputs the index.
Reading DPM 2D Codes
[Output
135

Advertisement

Table of Contents
loading