• You can change the output form for each measurement value to one of the following settings.
− [Result type] on the right of the display.
]
Press [
Absolute value (default): The measured coordinates are output as absolute values.
Relative value: The difference from the reference value is output.

Reflect in Total Judgement

You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
[Inspection]
parameter]

Increasing Measurement Position Accuracy

You can increase the accuracy of measurement positioning.
You can calculate down to four decimal places.
[Inspect] − [Inspection] − [Sensitive Search] − [Modify] − [Details] Tab Page − [Meas.
Parameter]
1
Press [Sub-pixel] and select [Yes].

Select the Results to Output

You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect] − [Inspection] − [Sensitive Search] − [Modify] − [Details] Tab Page − [Meas.
Parameter]
1
Press [Candidate level] and adjust the candidate lev-
el so that only objects higher than a certain correla-
tion are detected.
Extraction condition Range
Candidate level
0 to 100
Note
The processing time changes if you change the candidate level.
FQ2-S4 User's Manual
[Add item.]
[Sensitive Search]
Inspecting with the Sensitive Search Inspection Item
[Details] Tab Page
Description
Only objects with a correlation that is higher than the
specified candidate level are output.
[Output
157