Omron FQ2-S4 User Manual page 339

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Parameter
Description
Timeout
This parameter is displayed and can be set only
when [Handshake setting] is set to [Yes].
A timeout error will occur if there is no response
from the PLC within the time that is set.
• From when measurements are completed
until the DSA Bit turns ON
• From when the GATE flag turns ON until the
DSA Bit turns OFF
• From when the GATE flag turns OFF until the
DSA Bit turns ON
Data output period This parameter is displayed and can be set only
when [Handshake setting] is set to [No]. Set the
period for outputting measurement results.
Important
Set a value that is longer that the GATE ON
output time and shorter than the measurement
interval of the Sensor.
GATE signal ON
This parameter is displayed and can be set only
period
when [Handshake setting] is set to [No].
Set the time to turn ON the GATE signal.
Set the time that is required for the PLC to read
the measurement results.
Important
Set the cycle time of the PLC so that it is longer
than the packet interval (RPI).
FQ2-S4 User's Manual
Setting range
0.1 to 120.0 s (default: 10 s)
2 to 5,000 ms (default: 40 ms)
1.0 to 1,000.0 ms (default: 20.0 ms)
Outputting Data and Controlling Operation through EtherNet/IP