Changing The Character String That Is Output For Read Errors; Changing The Items That Are Displayed On The Test Measurement And Run Display; Unstable Reading Results - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Note
The read character string is output after the other output data (data 0 to 31 in the output data settings) after the mea-
surement, such as the inspection item parameters and calculation results. Refer to the following section for the loca-
tion of the output area for the character string and other details.
Order in Which Data Is Written When Both Output Data and the Character String Are Output: p. 347, p. 383

Changing the Character String That Is Output for Read Errors

You can change the character string that is output for read errors.
[Inspect]
[Inspection]
[Error string]
Setup Item
Error string

Changing the Items That Are Displayed on the Test Measurement and Run Display

To change the items that are displayed on the test measurement and run display, press [Test] − [Continuous
test] − and then use
Display setting
Num. of char.
Characters

Unstable Reading Results

Reading Is Unstable Due to Low Contrast
Adjust the brightness to improve the contrast of the 2D code.
Adjusting the Brightness: p. 61
126
Reading 2D-codes
[Add item.]
[2D-code]
Setting Value
Description
Max. 20 digits (default value:
Sets the text string to be output when a read error occurs.
NG)
− [Display setting] on the Test Display.
[Details] Tab Page
ASCII code table: p. 116
Description
Displays the number of characters that were read.
Displays the character string that was read.
[Output parameter]
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading