Omron FQ2-S4 User Manual page 51

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

I/O Signal Circuit Diagrams
NPN
Input Circuit
Input terminal
3 KΩ
+
COM_I
PNP
Input Circuit
3 KΩ
Input terminal
+
COM_I
Important
Preventing Chattering
• The Sensor is equipped with an anti-chattering function, but if the chattering is 100 µs or longer, a faulty input may
occur. (Input signals of 99 µs or shorter are ignored. Signals of 100 µs or longer are treated as input signals.)
• Use no-contact output devices (e.g., SSR or PLC transistor output) for the input signals. If contacts (e.g., a relay)
are used, chattering may cause the trigger to be input again during execution of a measurement.
Power Supply Specifications When a Switching Regulator Is Connected
Use a power supply that meets the following specifications. (They are sold separately.)
Item
Power supply voltage
Recommended Power Supplies
External power supply terminal screws
Important
Supply power from a DC power supply for which measures have been applied to prevent high voltages (e.g., a safety
extra-low-voltage circuit).
If UL certification is required for the overall system, use a UL Class II DC power supply.
FQ2-S4 User's Manual
Output Circuit
Internal
circuits
Output Circuit
Internal
circuits
Description
FQ2-S4@@@@@ connection
24 VDC (21.6 to 26.4 V)
S8VS-06024@ (24 VDC, 2.5 A)
M4 (tightening torque: 1.2 N·m)
Output terminal
L
Load
+
COM_O
COM_O
+
Load
L
Output terminal
FQ2-S4@-@@@ connection
S8VS-03024 (24 VDC, 1.3 A)
Wiring
49