5
Repeat the above procedure to register more than
one character string in the master data.
6
Press [Verif. master data] and select the character
string in the master data to use for verification.
7
Set the following verification conditions as required.
Parameter
Verif. master data
Master data regist.
Auto teach No.
8
Press [Back].
Note
ASCII code table
The following table shows the ASCII codes that can be used for manual registration of master data and also
for registering characters of Limits.
Lower 4 bits
132
Reading DPM 2D Codes
Setting
OFF (default)
Sets whether to verify the read character string against a character string
All master data
that is registered in the master data. To verify the read character string
Master data 0 to 31
against the master data, select the character string to use for verification.
---
Registers a character string in the master data.
OFF (default)
Sets the character string in which to automatically register the read result for
Master data 0 to 31
teaching from an external device.
Upper 4 bits
Description