Omron FQ2-S4 User Manual page 553

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Item
Inspection and ID models
Model
NPN
FQ2-
S40@@@@
PNP
FQ2-
S45@@@@
I/O specifi-
Input signals
7 signals
cations
Output signals
3 signals
Note: The assignments of the three output signals (OUT0 to OUT2) can be changed to the individual
judgements of the inspection items, the image input ready output (READY), or the external lighting tim-
ing output (STGOUT).
Ethernet specifi-
100Base-TX/10Base-T
cations
Communica-
Ethernet TCP no-protocol,
tions
Ethernet FINS/TCP no-protocol,
EtherNet/IP, or
PLC Link
I/O expansion
Possible by connecting FQ-SDU1@ Sensor Data Unit.
11 inputs and 32 outputs
RS-232C
Possible by connecting FQ-SDU2@ Sensor Data Unit.
Input specifica-
Refer to Table 2.
tions
Output specifi-
cations
Connection
Special connector cables
method
Power supply and I/O: 1 cable
(FQ-WD@@@)
Touch Finder and computer: 1
cable (FQ-WN@@@)
Indications
BUSY indicator (BUSY, green), Judgement result indicator (OR, orange), error indicator (ERROR, red),
Ethernet communications indicator (ETN, orange)
Note: The assignment of the BUSY indicator can be changed to a RUN indicator (display color: green).
Ratings
Power supply
21.6 to 26.4 VDC (including ripple)
voltage
Insulation resis-
Between all lead wires and case: 0.5 MΩ (at 250 V)
tance
Current con-
2.4 A max.
sumption
Environ-
Ambient temper-
Operating: 0 to 50°C
Storage: −25 to 65°C
mental
ature range
immunity
(with no icing or condensation)
Ambient humid-
Operating and storage: 35% to 85% (with no condensation)
ity range
Ambient atmo-
No corrosive gas
sphere
Vibration resis-
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
tance (destruc-
8 min each, 10 times
tion)
Shock resis-
150 m/s
tance (destruc-
tion)
Degree of pro-
IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted
tection
or connector cap is removed.)
FQ2-S4 User's Manual
FQ2-
S40@@@@-M
FQ2-
S45@@@@-M
• Single measurement input (TRIG)
• Control command input (IN0 to IN5)
• Control output (BUSY)
• Overall judgement output (OR)
• Error output (ERROR)
2
3 times each in 6 direction (up, down, right, left, forward, and backward)
FQ2-
FQ2-
S40@@@@-08
S40@@@@-08M
FQ2-
FQ2-
S45@@@@-08
S45@@@@-08M
Special connector cables
Power supply I/O and Sensor data units: 1 cable (FQ-WD@@@ and
FQ-WU@@@)
Touch Finder and computer: 1 cable (FQ-WN@@@)
Specifications and Dimensions
FQ2-S40-13
FQ2-S40-
13M
FQ2-S45-13
FQ2-S45-
13M
0.3 A max.
IEC 60529 IP40
551

Advertisement

Table of Contents
loading