When you have finished setting the coordinates for
all of the positions, press [Generate parameters].
12
The calibration parameters will be displayed.
The items in the calibration parameters are the same as
those for point specification.
Parameter
With this method, you directly enter values to set calibration.
The calibration parameters will be automatically calculated when you enter the following three parameters.
Parameter
Setting
Coordinate (coor-
Righthand or Lefthand
dinate system)
Default: Lefthand
Origin
Upperleft, Lowerleft, or
Center
Default: Lowerleft
Magnification
0.0001 to 9.9999
Default: 1.0000
242
Calibration
Description
Lefthand: The positive direction is clockwise when coordinates are specified.
Righthand: The positive direction is counterclockwise when coordinates are specified.
Lefthand
Coordinate
0
System
Y
Y
Righthand
Positive direction
Coordinate
System
0
Select the location of the origin of the coordinate system.
Upper left
Center
Lower left
Set the actual dimension that corresponds to one pixel.
X
Positive direction
X
FQ2-S4 User's Manual