Outputting Read Characters To An External Device; Changing The Character String That Is Output For Read Errors - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Setup Item
Setting Value
Code type
JAN/EAN/UPC (default
value)
Code39
Codebar
ITF
Code93
Code128/GS1-128
GS1 DataBar
Pharmacode
Composite codes on/off
No (default value)
Yes
Check digit on/off
No (default value)
Yes
Direction
Horizontal mode (default
value)
Vertical mode
Reverse on/off
No (default value)
Yes
Timeout
1 to 9999 ms (default value:
9999)

Outputting Read Characters to an External Device

After a measurement, you can automatically output the character string that was read with the barcode
inspection item to a PLC or other external device. The character strings are output after outputting the output
data (output data settings 0 to 31), such as the inspection item parameters and calculation result.
Refer to the description for the communications format for the setting procedure and output specifications to
output the character string.
Outputting Character Strings
• EtherNet/IP: p. 346
• PLC Link: p. 383
• TCP No-protocol Communications: p. 408
Note
The read character string is output after the other output data (data 0 to 31 in the output data settings) after the mea-
surement, such as the inspection item parameters and calculation results.
Refer to the following section for the location of the output area for the character string and other details.
Order in Which Data Is Written When Both Output Data and the Character String Are Output: p. 347, p. 383

Changing the Character String That Is Output for Read Errors

You can change the character string that is output for read errors.
[Inspect]
[Inspection]
[Error string]
FQ2-S4 User's Manual
Description
Selects the type of barcode to be read.
Sets whether or not to support composite codes.
This item is enabled only when the following barcode types are selected:
Code128/GS1-128, GS1-DataBar
Selects whether or not to insert a check digit. This item is enabled only
when the following barcode types are selected: Codebar, Code39, ITF
(Interleaved 2 of 5), JAN, EAN, UPC, or Code93. When the other codes
are selected, this item is set to ON.
Selects the reading direction. This item is enabled only when Pharma-
code is selected as the barcode type.
Sets whether or not to use the reverse mode. This item is enabled only
when Pharmacode is selected as the barcode type.
Sets the timeout time in read processing. A read error occurs if measure-
ment does not end after the preset timeout time is exceeded.
[Add item.]
[Bar code]
[Details] Tab Page
[Output parameter]
117
Reading Bar Codes

Advertisement

Table of Contents
loading