Set Inspection Item Data
This command sets the parameters and measurement values of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
or
I
D
Inspection item
Command
number
(2 digits max.)
Space
Space
(0x20)
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Acquired value
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with TCP No-protocol Communications
Inspection
item number
(2 digits max.)
A
T
A
Space
(0x20)
External reference
data number
(4 digits max.)
Space
(0x20)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number. (0 to 9999)
12-2 External Reference Parameters: p. 491
Returns the data for the specified inspection item.
12-2 External Reference Parameters: p. 491
External reference
data number
(4 digits max.)
Space
Space
(0x20)
(0x20)
Setting
CR
Set value
Delimiter
Set value
CR
Setting
Delimiter