Item
Judgement Parameter
Note
• You can change the output form for each measurement value to one of the following settings.
− [Result type] on the right of the display.
Press
[
]
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
Ratio: The percentage of the reference value is output. (This applies to the area only.)

Reflect in Total Judgement

You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
[Inspection]

Unstable Area Results

The Desired Color Cannot Be Detected
Add a specific color or enlarge the color range.
Extraction Is Automatically Performed for an Undesired Color When Teaching
Manually set the color for which to measure the area.
− [Inspection] −
[Inspect]
• Sensors with Color Cameras Only
1
] − [Set color] on the right of the display.
Press [
2
Drag around the color for which you want to measure
the area.
Areas with that color will be automatically detected.
Continuous measurements will be performed for the im-
ages that are displayed.
Only the extracted color will appear on the display.
3
Press [OK].
4
Press [TEACH].
5
Press [Back] to end teaching.
184
Inspecting with the Area Inspection Item
Parameter
Setting
Area
Range: 0.00000 to 999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: 0.0000
Range: −999,999,999.9999 to
Gravity X
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
Range: −999,999,999.9999 to
Gravity Y
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
[Add item.]
[Area]
[Area]
[Modify]
[Details] Tab Page
[Settings] Tab Page
Description
Set the upper and lower limits for an OK
judgement. The set range is the differ-
ence between the reference area and
the measured areas.
Set the upper and lower limits of the
range of gravity X that is to be judged
as OK.
Set the upper and lower limits of the
range of the gravity Y that is to be
judged as OK.
[Output parameter]