Controlling Operation And Outputting Data With A Parallel Interface Sensor Data Unit; Overview; Setting The Measurement Trigger - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

8-2 Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit

Overview

If you mount a Parallel Interface Sensor Data Unit, in addition to outputting OR judgement results, you can also
use the Parallel Interface Sensor Data Unit to output the judgement results of judgement conditions that you set
for parallel output (called parallel judgement output) and the results of measurement values and expressions
for inspection items (called parallel data output).
External device

Setting the Measurement Trigger

The measurement trigger can be chosen from the following two types:
• Single measurement: One measurement is performed for each external trigger.
• Continuous measurement: Measurements are performed continuously.
Refer to the following page for data output timing and signal status after measurement trigger execution.
Aligning the Data Output Timing with the External Device: p. 308
Performing One Measurement for Each External Trigger
A measurement trigger is input as the TRIG signal from a proximity sensor, PLC, or other external device.
One measurement is performed when the TRIG signal turns ON.
Trigger input Sensor
302
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
• Measurement trigger
(single/continuous measurements)
• Control commands
Output Data
• OR judgement result
• Parallel judgement output
• Parallel data output
(1) TRIG signal ON
Or other
device
Sensor Data Unit
(2) Performs
measurements once
Sensor
FQ2-S4 User's Manual