Omron FQ2-S4 User Manual page 389

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Signal
Signal name
Command code
Command code
Response code
Response code
Response data
Response data
● Output Area
Vision Sensor (Slave) to PLC (Master)
First
Bits
word
15
14
13
12
+0
+1
·
·
·
+14
+15
·
·
·
+128
+129
·
·
·
+512
+513
Signal
Signal name
DATA0-255
Output data 0 to 255
Note
If the size of data that is output exceeds the set value of the number of output data upper value setting, the remain-
ing data will be discarded.
Allocating Output Data p. 381
FQ2-S4 User's Manual
Function
This I/O port returns the command code that
was executed.
This I/O port contains the response code of the
executed command.
This I/O port contains the response data of the
executed command.
11
10
9
8
7
DATA 0
·
·
·
DATA 7
·
·
·
DATA 63
·
·
·
DATA 255
Function
These I/O ports output the output data that is
specified for the data output method.
The range of the data that can be output is
determined by the set value of the [Max output
data] (number of output data upper value)
parameter setting as follows:
Minimum setting (32 bytes): Output data 0 to 7
Default setting (256 bytes): Output data 0 to 63
Maximum setting (1,024 bytes): Output data 0
to 255
6
5
4
3
2
PLC Link Connections
Application
Command/
response commu-
nications
Contents
1
0
Output data
0 (32 bits)
·
·
·
Output data
7 (32 bits)
·
·
·
Output data
63 (32 bits)
·
·
·
Output data
255 (32 bits)
Application
Data output after
measurements
387

Advertisement

Table of Contents
loading

Table of Contents