Getting the Inspection Item Data: 280F 00401020
This command acquires the parameters and measurement values of the specified inspection item.
● Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00401020
● Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
● End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
● Parameter Descriptions
Inspection item number
Specifies the number of the inspection item for which to acquire the data.
External reference num-
Specifies the external reference number.
ber
12-2 External Reference Parameters: p. 491
Acquired value
Returns the data for the specified inspection item.
12-2 External Reference Parameters: p. 491
FQ2-S4 User's Manual
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
Inspection item number (4 bytes) External reference
Inspection item number from 00
to 1F (2 digits max.)
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00401020
number (4 bytes)
External reference
number
Acquired value (4
bytes)
Acquired value
(1,000 times the
actual value)
441