Menu Tables; Image Tab Page - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

12-1 Menu Tables

Image Tab Page

Menu command
Focus
Image mode
Shutter speed
(Normal mode)
Gain
(Normal mode)
Brightness
(HDR mode)
HDR
Brightness correc-
tion
White balance
Partial input
Rotate 180
Calibration setting
Strobe output delay
Strobe output time
Trigger delay
458

Menu Tables

Description
The value shown here is used as a refer-
ence when adjusting the focus with the
focus adjustment screw.
Pixel sampling can be applied to the
input image to reduce image input time.
Sets the shutter speed for Normal Mode. FQ2-S4@-@@@
If the gain is high, the image will be
bright. If the gain is low, the image will be
dark.
Sets the brightness level of the image for
HDR Mode.
Suppresses reflections and differences
in brightness.
Use to stabilize the brightness.
Corrects differences in coloring between
the image and the actual object.
Used to make the image input range
smaller.
You can rotate the Camera image by
180°.
Sets a registered calibration pattern.
Sets the delay time for the strobe output
signal (STGOUT) in response to the trig-
ger signal.
Sets the output time of the strobe output
signal (STGOUT).
Adjusts the time until the Camera shutter
opens after the trigger signal is received.
Setting range
---
Normal (default) or Fast
1/1 to 1/60,000
FQ2-S4@@@@@-08@
1/1 to 1/60,000
1/250 to 1/60,000 (for Sensors with
Built-in Lighting)
FQ2-S4@@@@ or FQ2-S4@@@@-M
1/1 to 1/50,000
1/250 to 1/50,000 (for Sensors with
Built-in Lighting)
Default: 1/250
For FQ2-S4@@@@@-08@,
FQ2-S4@-@@@
Range: 0 to 10 (default: 10)
For FQ2-S4@@@@@@,
FQ2-S4@@@@@@-M
Range: 16 to 64 (default: 16)
1 to 100
OFF(default), Level 1 to Level4
ON or OFF (default)
• AUTO
• R: 0.001 to 7.999
• G: 0.001 to 7.999
• B: 0.001 to 7.999
FQ2-S4@@@@@/FQ2-S4@@@@@-M:
752×8 to 752×480
FQ2-S4@@@@@@-08@:
928×8 to 928×828
FQ2-S4@-@@@: 1280×8 to
1280×1024
ON or OFF (default)
Unregistered (default), New Calibra-
tion, or Calibration Data 0 to 31
0 to 65,535 µs (default: 0 µs)
0 to 65,535 µs (default: 1,000 µs)
0 to 163 ms (default: 0)
Data
Refer-
ence
---
p. 60
Scene
p. 218
Scene
p. 63
Scene
p. 63
Scene
p. 63
Scene
p. 65
Scene
p. 66
Scene
p. 66
Scene
p. 217
Scene
p. 278
Scene
p. 243
Scene
p. 316
Scene
p. 316
System
p. 67
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading