• Measurement Data
1
Press [Data logging]
2
Change the logging conditions, and then press
[Back].
Item
Image logging (image data)
Data logging (measurement
data)
Note
The logging parameter settings are the same for recent results logging.
Selecting the Measurement Data To Log
Use the following procedure to select the measurement data to log.
[In/Out] − [Log setting] − [Measurement data] − [Select data]
1
Press the inspection item or expression that has the
parameter for which to log data.
2
Press the parameter for which to log data to select it.
Note
The procedure to select the measurement data to log is the same for recent results logging.
254
Logging Measurement Data and Image Data
[Condition].
Description
• All: All images will be logged regardless of the measurement results.
• Only NG: Only images for which the overall judgement was NG will be logged.
• None: No images will be logged (default).
• All: All measurement data (Measured values and calculation results) will be logged regardless of the
measurement results.
• Only NG: Only measurement data (Measured values and calculation results) for which the overall
judgement was NG will be logged.
• None: No measurement data (Measured values and calculation results) will be logged (default).