Setting The Outputs - Omron FQ2-S4 User Manual

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Setting the Outputs

Using the Overall Judgement Result
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Individual judgement results
Inspection
item 0
Inspection
item 1
Inspection
item 31
Expression
Note
• The overall judgement result output signal can also be turned ON when all individual judgement results are OK.
Changing the judgement output ON condition: p. 290
• You can select whether to include the judgement result of one of the expressions (0 through 31) in the overall
judgement.
Using Calculation Results without Applying Them to the Overall Judgement: p. 203
• You can adjust the timing for outputting the OR signal and the ON time after judgement processing.
Adjust the Judgement Output Timing: p. 288
Wiring
Color
Signal
Black
OUT0 (OR)
Timing Chart
The OR signal that is output is held until the next overall judgement is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
OR signal
286
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
OK
Overall judgement
NG
NG (OR signal ON)
If there is even one NG judgement,
the overall judgement will be NG
OK
and the output will be turned ON.
OK
Description
Overall judgement (default
assignment)
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
The signals shown at the left are used.
Refer to the following information for signal wiring.
2-4 Wiring: p. 42
Overall judgement
Turned ON when overall
judgement is NG.
(OR output: ON for NG)
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading

Table of Contents