FQ-SDU10/SDU15 Terminal Signal Names
Pin
Signal
IN/
Function
OUT
1
COMOUT1
-
Output signal common (DO0 to
DO15)
*1
2
NC
-
3
D0
OUT
Data output
4
D1
OUT
Data output
5
D2
OUT
Data output
6
D3
OUT
Data output
7
D4
OUT
Data output
8
D5
OUT
Data output
9
D6
OUT
Data output
10
D7
OUT
Data output
11
D8
OUT
Data output
12
D9
OUT
Data output
13
D10
OUT
Data output
14
D11
OUT
Data output
15
D12
OUT
Data output
16
D13
OUT
Data output
17
D14
OUT
Data output
18
D15
OUT
Data output
*1
19
NC
-
*1
20
NC
-
*1
21
NC
-
*1
22
NC
-
*1
23
NC
-
*1
24
NC
-
*1
25
NC
-
*1
26
NC
-
*1
27
NC
-
*1
28
NC
-
*1
29
NC
-
*1
30
NC
-
*1:
Leave all signal terminals that are labeled "NC" open.
*2:
You can select whether to turn the external lighting ON (Positive) or OFF (Negative) when the signal turns ON. (The setting is called the
strobe output polarity.)
Changing the Output Timing and Output Time of the STGOUT Signal: p. 316
*3:
This control signal is used to turn ON external lighting when an image is taken. Connect this signal to external lighting.
*4:
This signal is output to an external device when exposure of the imaging elements is completed. If you want to move the Sensor to the next
measurement location after a measurement is completed, move the Sensor only after this signal turns ON.
Shutter Output Signal (SHTOUT)
ON
Trigger input (TRIG)
OFF
ON
Imaging element
shutter signal
OFF
ON
SHTOUT
OFF
The SHTOUT signal turns ON for approximately 10 ms (fixed) when the shutter time (exposure period) elapses after
the trigger is input from an external device.
FQ2-S4 User's Manual
Pin
Signal
31
COMIN0
32
COMIN1
33
TRIG
*1
34
NC
*1
35
NC
36
RESET
37
IN0
38
IN1
39
IN2
40
IN3
41
IN4
42
IN5
43
IN6
44
IN7
*1
45
NC
*1
46
NC
47
DSA
*1
48
NC
*1
49
NC
*1
50
NC
*1
51
NC
52
ACK
53
RUN
54
BUSY
55
OR
56
ERROR
57
STGOUT
58
SHTOUT
59
GATE
60
COMOUT0
Trigger delay
Shutter time
10 ms
IN/
Function
OUT
-
Input signal common (all inputs
except TRIG)
-
Input signal common (TRIG)
IN
Measurement trigger input
-
-
IN
Reset input
IN
Command input
IN
Command input
IN
Command input
IN
Command input
IN
Command input
IN
Command input
IN
Command input
IN
Command input
-
-
IN
Data send request signal
-
-
-
-
OUT
Command execution completed
flag
OUT
ON during measurement mode
OUT
ON during process execution
OUT
Overall judgement result
OUT
ON during error
*2, *3
OUT
Strobe trigger output
*4
OUT
Shutter trigger output
OUT
ON during the set output time.
-