Omron FQ2-S4 User Manual page 322

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

Clearing an Error
This command clears the error output status.
Parameters
Execution
Command
IN7
IN6
1
1000001
Timing Chart
ON
RUN signal
OFF
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON
ON
OR signal
OFF
OFF
D signals
ON
ON
GATE signal
OFF
OFF
ON
ON
ERROR signal
OFF
OFF
IN0 to IN6
signals
Allow 5 ms min. and then turn ON IN7.
ON
IN7 signal
OFF
ON
ACK signal
OFF
320
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
IN5
IN4
IN3
Run Mode entered.
ON for 1 ms min.
TRIG is input.
Measurements executed.
Data
GATE ON delay
Output time
IN2
IN1
IN0
Setup Mode entered.
1000001
ON for 1 ms min.
ACK output time
Input example
11000001
FQ2-S4 User's Manual

Advertisement

Table of Contents
loading

Table of Contents