Omron FQ2-S4 User Manual page 353

Smart camera
Hide thumbs Also See for FQ2-S4:
Table of Contents

Advertisement

• Output Area
The output area is assigned immediately after the response area in I/O memory.
15
14
13
+8
+9
·
·
·
+22
+23
·
·
·
+38
+39
·
·
·
+70
+71
·
·
·
+134
+135
Signal
Signal name
DATA0-63
Output data 0 to 63
FQ2-S4 User's Manual
Bits
12
11
10
9
8
DATA 0
DATA 7
DATA 15
DATA 31
DATA 63
Function
These I/O ports output the output data that is
specified for the data output method.
The data that can be output is determined by
the set value of the Output data size setting as
follows:
32 bytes: Output data 0 to 7
64 bytes: Output data 0 to 15
128 bytes: Output data 0 to 31
256 bytes: Output data 0 to 63
Outputting Data and Controlling Operation through EtherNet/IP
7
6
5
4
3
·
·
·
·
·
·
·
·
·
·
·
·
Contents
2
1
0
Output data
0 (32 bits)
·
·
·
Output data
7 (32 bits)
·
·
·
Output data
15 (32 bits)
·
·
·
Output data
31 (32 bits)
·
·
·
Output data
63 (32 bits)
Application
Command/
response commu-
nications
351