4.11.4. Replacing the waste bottle box sensor assembly (F2O 4H)

Step 1 :
Follow the instructions in "Replacing the waste fluid bottle assembly" to remove the waste fluid bottle assembly.
Caution :
Waste ink will remain inside the tubes. Be careful that the ink is not spilled from the tube
onto the printer or items close to the printer.
Step 2 :
Remove the waste liquid BOX sensor assembly connector from the rear side cap R.
1 = Rear side cap R
Step 3 :
Remove the waste liquid box assy from the stand.
Falcon II Outdoor series printers – Maintenance Manual
2 = Waste liquid BOX sensor assembly connector