7.15. PUMP TUBING LAYOUT FOR PUMP ASSEMBLY

7.15.1. Replacing the pump assembly (Rockhopper 4 heater)

(1) For 50 or 64 inch spec
Notes :
When the pump assembly has been installed to the main body, "pump 1" is the
pump on the left and "pump 2" the one on the right, viewed from the front.
1 = Pump 1
Step 1 :
Remove the maintenance cover.
Step 2 :
Following the instructions in "Self-Diagnosis Functions" to start the equipment up in the self-diagnosis mode and
release the head lock.
Step 3 :
Disconnect the tubes to the heads.
Step 4 :
Remove the waste tubes from there connector.
1 = connection to the heads
Falcon II Outdoor series printers – Maintenance Manual
2 = Pump 2
2 = waste tube connection