3.12 Replacing Accessory Unit

3.12 Replacing Accessory Unit
3.12.1
Replacing Waste Fluid Level Switch ,Waste Fluid Bottle
Assy
T I P
Replacing Procedure For Maintenance Part: Waste Fluid Level Switch (VJ16) and Waste Fluid Bottle
Assy.
This part will be referred to as the Waste Fluid Switch and Waste Fluid Bottle Assy in this manual.
NOTE
• Discharge the waste fluid fully to replace Waste fluid bottle.
• Confirm that there remains no waste fluid in the waste fluid tube.
1. Remove waste fluid level switch from connector.
2
No.
1
Waste fluid level switch
Connector
2
2.
Remove Waste fluid tube.
3.
Loosen Cap of Waste fluid bottle.

3.12.1 Replacing Waste Fluid Level Switch ,Waste Fluid Bottle Assy

1
Name
4.
Loosen the nut of Waste fluid level switch.
4
3
No.
1
Waste fluid bottle
2
Waste fluid tube
3
Cap of Waste fluid bottle
4
Nut of Waste Fluid Level switch
5.
Pull out the nut of Waste fluid level switch and Waste fluid bottle cap from Waste fluid bottle.
No.
1
Cap of Waste fluid bottle
2
Nut of Waste fluid level switch
6.
Replace Waste fluid bottle.
7.
Replace Waste Fluid Level switch.
8.
To reassemble unit, reverse the removal procedure.