Pf Motor Endurance Menu - MUTOH Falcon II Outdoor Maintenance Manual

Eco-solvent plus
Table of Contents

Advertisement

5.9.2. PF Motor Endurance Menu

This menu performs endurance running for the PF motor.
You can drive the PF motor according to your desired settings. The available settings are shown below.
Setup item
Media feed amount
Number of endurance
running cycles
Notes :
* FeedAmount *
* LifeCount *
Count
* PFmotor *
Count
* PFmotor *
End
Description
Sets amount of media
feeds per endurance
operation.
Set the number of
endurance running
cycles
The motor drive parameters are determined as follows depending on the media feed
amount.
Speed
Acceleration
Deceleration
If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
0 – 100.0 mm +
↓ ENTER
↓ ENTER
↓ ENTER
Falcon II Outdoor series printers – Maintenance Manual
Parameters
0 to 100
-1 to 10000
54 cps
0.1 G
0.1 G
Media feed amount
0.1 mm -
-1 → 10000 +
Number of endurance running cycles
50 -
5
Perform endurance running
50
199
Remarks
Unit: mm
AP-74065, Rev. 1.0, 21/11/03