Step 6 :
Apply the screw lock to the cursor axis, and install the cursor roller assembly with the axis at the lower position.
Notes :
1 = Applying position of the screw lock
Step 7 :
Perform head height adjustment according to "Head height adjustment".

4.8. REPLACING THE MAINTENANCE AREA

4.8.1. Replacing the maintenance assembly

Notes :
Step 1 :
Follow step 1 in "Replacing the flushing box assembly" to move the CR cursor to the left.
Step 2 :
Remove the 4 screws fixing the side plate T.
Be sure that the screw lock does not contaminate the cursor roller or the spacer.
When replacing the parts inside the maintenance assembly, be sure to perform
following operation to clear the counter.
"High ink initialization" or " Cleaning initialization": refer to "Counter Display
Menu"
Remove following covers before replacing the parts inside the maintenance
assembly.
Side cover R: refer to "Removing side cover R"
Side cover L: refer to "Removing side cover L"
Front cover: refer to "Removing the front cover"
Carriage cover: refer to "Removing the carriage cover"
Y rail cover: refer to "Removing the Y rail cover"