Heating System Error - MUTOH Falcon II Outdoor Maintenance Manual

Eco-solvent plus
Table of Contents

Advertisement

9.2.3. Heating system error

The following explains the messages, items to be confirmed and remedies to take when errors handling heating system
occur while the product is operating.
Heating system errors are displayed when communication trouble occurs between the heater strips and this product.
If heating system error occurs, the following error messages are displayed and the printer stops.
Solve the problem to delete the error message and restart the printer.
No
Message
1
AC not present
2
Error sensors A
3
Error sensor A
4
Conn. err. Left A
5
Conn. err. Right A
6
Error sensors D1
7
Error sensor D1
8
Conn. err. Left D1
9
Conn. err. Right D1
10
Error sensors D2
11
Error sensor D2
12
Conn. err. Left D2
13
Conn. err. Right D2
14
Couldn't reach temp
15
Err: Temp > 85°C!
16
Connection err. A
17
Connection err. D1
18
Connection err. D2
19
Error sensor B1
20
Error sensor C
21
Connection err. B1
22
Connection err. C
23
Error sensor B2
24
Connection err. B2
25
Error D group
26
Error A group
27
Error B group
Important :
Before checking the connectors, please power off the unit and remove the power
cable.
Falcon II Outdoor series printers – Maintenance Manual
Check point
Action
AC connector.
Check AC connector
Sensors A
Check if the sensors are connected properly.
Sensor A
Check if the sensors are connected properly.
Sensor A
Check if the left sensor is connected properly.
Sensor A
Check if the right sensor is connected properly.
Sensors D1
Check if the sensors are connected properly.
Sensor D1
Check if the sensors are connected properly.
Sensor D1
Check if the left sensor is connected properly.
Sensor D1
Check if the right sensor is connected properly.
Sensors D2
Check if the sensors are connected properly.
Sensor D2
Check if the sensors are connected properly.
Sensor D2
Check if the left sensor is connected properly.
Sensor D2
Check if the right sensor is connected properly.
Heater strip
After 10 minutes, temperature is not reached. Check
the heater strips.
Heater strip
Temperature comes higher then the limit. Check the
heater strips.
Rear Heater (A)
Check the connector of the rear heater.
Dryer (D1)
Check the connector of the front heater (D1).
Dryer (D2)
Check the connector of the front heater (D2).
Fixer (B1)
Check the sensor of the fixer 1 (B1).
Post fixer (C)
Check the sensor of the fixer (C).
Fixer (B1)
Check the connector of the fixer 1 (B1).
Post fixer (C)
Check the connector of the post fixer (c).
Fixer (B2)
Check the sensor of the fixer 2 (B2)
Fixer (B2)
Check the connector of the fixer 2 (B2).
Heaters D
Temperature difference higher then 15°C between
the sensors of the D heaters.
Heaters A
Temperature difference higher then 15°C between
the sensors of the A heaters.
Heaters B
Temperature difference higher then 15°C between
the sensors of the B heaters.
286
AP-74065, Rev. 1.0, 21/11/03

Advertisement

Table of Contents
loading