General Endurance Menu - MUTOH Falcon II Outdoor Maintenance Manual

Eco-solvent plus
Table of Contents

Advertisement

5.9.9. General Endurance Menu

This menu performs the general endurance running.
You can operate various driving systems according to your desired settings.
The available settings are shown below.
Setup item
Operation speed (CW,
CCW)
Media feed amount
Number of endurance
running cycles
Notes :
* Speed CW *
Speed
* Speed CCW *
Speed
* Feed Amount *
* Life Count *
Count
Description
Sets carriage operation
speed (CW and CCW).
Set the media feed
amount per cycle
Set the number of
endurance running
cycles
If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
240 / 300 +
240 cps -
↓ ENTER
240 / 300 +
240 cps -
↓ ENTER
0 – 100.0 mm +
0.1 mm -
↓ ENTER
-1 → 10000 +
↓ ENTER
Falcon II Outdoor series printers – Maintenance Manual
Parameters
240/300
0 to 100
-1 to 10000
Speed (CW)
Speed (CCW)
Media feed amount
Number of total endurance running cycles
50 -
208
Remarks
Unit: cps
Unit: mm
AP-74065, Rev. 1.0, 21/11/03

Advertisement

Table of Contents
loading

Table of Contents