7.11. COVER SENSOR ADJUSTMENT

This section explains the procedure for adjusting the cover sensor.
When replacing the cover sensor assembly or removing/installing the front cover, use this procedure to adjust the cover
sensor.
Step 1 :
Start the self-diagnostic function.
Notes :
Refer to "Self-Diagnosis Function ".
Step 2 :
Select "Check:Test" on the self-diagnostic menu.
Step 3 :
In the inspection menu, select "Check : Check".
Step 4 :
Select "Sensor:Etc." on the sensor menu.
Step 5 :
Open and close the front cover assembly and make sure the dimension between the media guide and the front
cover end is 21 mm, and the display in the operation panel is switched as follows.
Notes :
Use a block gauge to measure the height of the front cover when opening it.
Step 6 :
If the opening height of the front cover and the information displayed on the operation panel are different, adjust
the installation position of the sensor cam.
Front cover
Open
Closed
247
Falcon II Outdoor series printers – Maintenance Manual
Operation panel display
Sensor: open
Sensor: closed
AP-74065, Rev. 1.0, 21/11/03