5.5.7. Band Feed Correction Menu (X Length)

In this menu, you can correct the media feed distance.
To correct the media feed distance, you must first print out check patterns and measure the distance between lines drawn
in the media feed direction. Then you enter the measured value through this menu.
The system uses this entered value to determine the PF encoder resolution parameter in the firmware.
To perform an X-length Adjustment, please follow the steps mentioned below.
Step 1 :
Go to Feed Adjustment.
Step 2 :
Set the parameter value to 900 mm.
Step 3 :
Print out the Feed Adjustment pattern.
Step 4 :
Measure the printed Band Feed Correction pattern.
Step 5 :
Enter the measured value as the Media Feed Distance parameter.