Predefined user roles
network-admin
network-operator
Parameters
interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no
interface is specified, this command displays the current values of the digital diagnosis parameters
on every transceiver module.
Examples
# Display the current values of the digital diagnosis parameters on the transceiver module in
interface Ten-GigabitEthernet 1/0/1.
<Sysname> display transceiver diagnosis interface
Ten-GigabitEthernet1/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
36
Alarm thresholds:
High
Low
Table 10 Command output
Field
transceiver diagnostic information
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBm)
TX power(dBm)
display transceiver interface
Use display transceiver interface to display the key parameters of transceiver modules.
Syntax
display transceiver interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type interface-number: Specifies an interface by its type and number. If you do not specify
an interface, this command displays the key parameters of every transceiver module.
Voltage(V)
Bias(mA)
3.31
6.13
Temp(°C)
Voltage(V)
50
3.55
30
3.01
RX power(dBm)
-35.64
Bias(mA)
RX power(dBM)
1.44
-10.00
1.01
-30.00
Description
Digital diagnosis information for the transceiver module in the interface.
Temperature in °C, accurate to 1°C.
Voltage in V, accurate to 0.01 V.
Bias current in mA, accurate to 0.01 mA.
Receive power in dBm, accurate to 0.01 dBm.
Transmit power in dBm, accurate to 0.01 dBm.
24
ten-gigabitethernet 1/0/1
TX power(dBm)
-5.19
TX power(dBM)
5.00
0.00