Display Transceiver Interface - H3C S3610 Series Command Manual

System maintaining and debugging
Hide thumbs Also See for S3610 Series:
Table of Contents

Advertisement

Command Manual – System Maintaining and Debugging
H3C S3610&S5510 Series Ethernet Switches
Description
Use the display transceiver diagnosis interface command to display the currently
measured value of digital diagnosis parameters of a single or all anti-spoofing
transceivers customized by H3C.
Examples
# Display the currently measured value of digital diagnosis parameters of the
anti-spoofing pluggable optical transceiver customized by H3C on interface
GigabitEthernet 1/1/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 1/1/2
GigabitEthernet1/1/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
36
Table 3-7 Description on the fields of display transceiver diagnosis interface
transceiver diagnostic information
Current diagnostic parameters
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBM)
TX power(dBM)

3.1.14 display transceiver interface

Syntax
display transceiver interface [ interface-type interface-number ]
View
Any view
Voltage(V)
Bias(mA)
3.31
6.13
Field
3-14
Chapter 3 Device Management Commands
RX power(dBM)
TX power(dBM)
-35.64
-5.19
Description
Digital diagnosis information of the
transceiver carried by an interface
Current diagnostic parameters
Digital diagnosis parameter-temperature, in
°C, with the precision to 1°C.
Digital diagnosis parameter-voltage, in V, with
the precision to 0.01 V.
Digital diagnosis parameter-bias current, in
mA, with the precision to 0.01 mA.
Digital diagnosis parameter-RX power, in
dBM, with the precision to 0.01 dBM.
Digital diagnosis parameter-TX power, in
dBM, with the precision to 0.01 dBM.