Surface Volts
This option adjusts the drum surface voltage sensor. The normal setting is
approximately 580 (the default). The allowable range is 500 through 700, in
increments of 4 volts.
Bias Volts
This option adjusts the developer bias. Normal adjustment is as needed. The default
is 300 volts (or 340 for the new style of corona power supply). The allowable range
is 200 through 600, in increments of 10 volts.
LED Time
LED time is the amount of time the print–head LEDs remain illuminated when
triggered. The normal setting is approximately 25 micro–seconds (the default). The
allowable range is .25 through 50.00, in increments of .25 micro–seconds.
Cut–sheet X Adj. and Cut–sheet Y Adj.
These are master adjustments for image shift on cut–sheet forms, stored in the engine
(not PSA) NVRAM. Adjustment affects all forms and should be performed only by
service personnel. (To adjust image shift for specific forms, the user should use the
adjustment under the Paper Control menu.)
Normal adjustment is as needed. The allowable range is –1 inch through
+1 inch, in increments of 1/100 inch.
Fan–fold X Adj. and Fan–fold Y Adj.
These are master adjustments for image shift on fan–fold forms, stored in the engine
(not PSA) NVRAM. Adjustment affects all forms and should be performed only by
service personnel. (To adjust image shift for specific forms, the user should use the
adjustment under the Paper Control menu.)
Normal adjustment is as needed. The allowable range is –1 inch through
+1 inch, in increments of 1/100 inch.
Reset Toner Full
After replacing a full Waste Toner Bottle, clear Error 28 by pressing CLEAR and
going off–line. Enter the configuration menu and select the Printer Control menu.
Then select the "Reset Toner Full" option and press ENTER.
Troubleshooting
7–13