TPFA10
TPFB10
TPFA11
TPFB11
Further, the transfer elevator motor is controlled with the transfer unit always in the
highest position as standard. When initializing the machine, rotate this motor until the
upper limit sensor is off (highest position is detected), confirm the standard position,
output 100 pulses again, and control the transfer unit to the lowest limit. After this,
raise or lower the transfer unit whenever required by the process by outputing 100
pulses, and check the movement of the transfer unit each time with the transfer unit
upper limit/lower limit sensor.